HOW TO READ A MODEL NUMBER:

Each Marathon Electric motor carries a model number that can be used to define some of the motor's physical and electrical characteristics.

Example (For Fractional): 1PC48C17D2000AP

This is a breakdown of the model on the nameplate:

1  P  C   48   C  17   D   2000    A   P
1  2   3    4    5    6    7      10     11  12

This is a breakdown of the model in the catalog:

48  C  17  D   2000
4    5    6   7      10

Example (For Integral): 2QA215TBDRA7076ALL

This is a breakdown of the model on the nameplate:

2  Q   A  215T  B  D   R  A    7076   AL   L
1   2   3      4     5   7   8   9      10      11  12

This is a breakdown of the model in the catalog:

215T   B   D   R   A   7076
   4       5    7   8    9     10


1. Date Code - Year of Manufacture (Not shown in catalog listings.)

2. Thermal Protection:

 

UL Recognized
Motor
Protector Combination

UL Recognized
Motor
Construction

Automatic Reset

Automatic
Reset

Automatic Reset

Q

Yes

Yes

S

No

No

U

No

Yes

W

#

Yes

Manual Reset

Manual Reset

Manual Reset

P

Yes

Yes

Z

No

Yes

X

No

No

None

None

None

V

No

Yes

# Motor protector combination is U.L. recognized only if motor is used in direct drive fan duty application, and is under locked rotor condition, or is running under no-load condition.

3. Date Code - Month of Manufacturer (Not shown in catalog listings.)

4. NEMA Frame Size - (Integral motors - T and U designate standard shaft, TS and US designate short shaft, V    designates vertical hollow shaft.)

5. Electrical Type:

Single Phase:

A = Permanent split capacitor
B = Capacitor start, capacitor run
C = Capacitor start, induction run
N = Split phase start, capacitor run
S = Split phase

Three Phase:

T = Three phase
H = Inverter Duty/IEEE841 Inverter Duty Capable
V = Medium Voltage

6. RPM or Speed at 60 Hz (Fractional Only):

34 = 2-Pole, 3600 rpm
17 = 4-Pole, 1800 rpm
11 = 6-Pole, 1200 rpm
8 = 8-Pole, 900 rpm

7. Enclosure:

D = Dripproof
E = Explosion proof, non-ventilated
F = Totally enclosed, fan cooled
G = Explosion proof, fan cooled
O = Open
P = Partial
S = Semi-enclosed
T = Totally enclosed, non-ventilated

8. Frame Construction (Integral Only):

L = Aluminum (Full Frame)
Y = Aluminum (Redesign - Full Frame)
Z = Aluminum (Redesign - High Mount Down Frame)
H = Aluminum - Sourced
R = Rolled Steel (Full Frame)
W = Rolled Steel (Redesign - Full Frame)
X = Rolled Steel (Redesign - High Mount Down Frame)
B = Rolled Steel - Sourced
S = Cast Iron (Full Frame)
N = Cast Iron (Redesign - Full Frame)
P = Cast Iron (Redesign - High Mount Down Frame)
C = Cast Iron - Sourced

9. Style Letter

10. Sequence Number - Last 3 Digits (Integral Only)

001-025 = 2-Pole, 3600 rpm
026-075 = 4-Pole, 1800 rpm
076-100 = 6-Pole, 1200 rpm
101-125 = 8-Pole, 900 rpm

11. Minor Modification Letter(s): Fractional - 1 letter; Integral - 2 letters

12. Manufacturing Code